31 May 2019. pp. 433-452
Abstract
References
1
ACI (1999) 544, “State of the art report on fiber reinforced concrete technical report”, American Concrete Institute.
2
ASTM (2008), C1550, “Standard test method for flexural toughness of fiber reinforced concrete (using centrally loaded round panel)”, ASTM International, West Conshohocken, Pa.
3
ASTM (2012), C1609, “Standard test method for flexural performance of fiber-reinforced concrete (using beam with third-point loading)”, ASTM International, West Conshohocken, pa.
4
Buratti, N., Mazzotti, C., Savoia, M. (2010), “Experimental study on the flexural behaviour of fibre reinforced concretes strengthened with steel and macro-synthetic fibres”, Fracture Mechanics of Concrete and Concrete Structures - Assessment, Proceedings of FraMCoS-7, May 23-28, pp. 1286-1294.
5
EFNARC (2011), “Panel tests such as the square panel test”, Experts for Specialised Construction and Concrete Systems.
6
JSCE (1984), “Method of test for flexural strength and flexural toughness of steel fibre reinforced concrete”, Japanese Society of Civil Engineers, pp. 4.
7
Korean Tunnelling and Underground Space (2014), A study on the optimal construction method of rockbolt in the Seoul metropolitan rapid transit (Suseo-Pyeongtaek) construction project and tunnel stability review of steel fiber reinforced shotcrete lining quality improvement plan, pp. 251-300.
8
KS F 2405 (2017), “Standard test method for compressive strength of concrete”, National Institute of Technology and Standards, Korea.
9
KS F 2566 (2014), “Standard test method for flexural performance of fiber reinforced concrete”, National Institute of Technology and Standards, Korea.
10
Lee, S.Y., Park, Y.J., Kim, S.M., Yoo, G.H., Jang, S.I., Seo, Y.H. (2010), “A study on the performance evaluation of polypropylene fiber reinforced concrete”, Tunnel and Underground Space, Vol. 20, No. 5, pp. 378-389.
11
Ministry of Construction & Transportati (2004), A study on improvement of structural fiber reinforced shotcrete performance research report, Korea Agency for Infrastructure Technology Advancement, pp. 10-24, pp. 85-205.
12
Ministry of Land, Infrastructure and Transport (2017), A study on the revision of tunnel design criteria, pp. 5-28.
13
RTA (1999), T373, Determination of the toughness of a fiber reinforced shotcrete mix-round determinate panel test.
14
Yoshida, S., Taguchi, F., Kishi, N., Mikami, H. (2002), “Corroboration test of shotcrete lining method with short-fiber mixed mortar using prototype tunnel model”, Civil Engineering Research Institute of Hokkaido, Shotcrete For Underground Support IX, pp. 332-341.
Information
  • Publisher :Korean Tunneling and Underground Space Association
  • Publisher(Ko) :한국터널지하공간학회
  • Journal Title :Journal of Korean Tunnelling and Underground Space Association
  • Journal Title(Ko) :한국터널지하공간학회 논문집
  • Volume : 21
  • No :3
  • Pages :433-452
  • Received Date : 2019-04-08
  • Revised Date : 2019-05-03