All Issue

2020 Vol.22, Issue 4 Preview Page

Research Paper

31 July 2020. pp. 469-484
Abstract
References
1
Barbero, E.J., Sosa, E.M., Marinez, X., Gutierrez, J.M. (2013), "Reliability design methodology for confined high presssure inflatable structures", Engineering Structures, Vol. 51, pp. 1-9.
10.1016/j.engstruct.2013.01.011
2
Kenyon, P. (2012), 35,000 Gallons of preventioncontaining a tunnel flood with an inflatable stopper, Tunnel Talk.
3
Kim, Y.D., Kong, M.T., Hwang, B.H., Kim, S.H. (2018), "An experimental study on the operation mode of rapid flooding protection system in tunnel", Journal of Korean Tunnelling and Underground Space Association, Vol. 20, No. 6, pp. 1147-1159.
4
Kim, Y.I., Cho, S.K. (2003), "Determination of segment sealing material for a subaqueous tunnel under the Han river in the Bundang railway", Proceedings of the 2003 Korean Society of Civil Engineers of Conference, Daegu, pp. 5414-5426.
5
Korea Institute of Civil Engineering and Building Technology (2010), Road design manual part 6 tunnel, Ministry of Land, Infrastructure and Transport, pp. 607, 17-607, 18.
6
Korean Concrete Society (2012a), Standard analysis of concrete structure, Kimoondang, Seoul, pp. 66-72.
7
Korean Concrete Society (2012b), Standard analysis of concrete structure, Kimoondang, Seoul, pp. 73-81.
8
Martinez, X., Davalos, J.F., Barbero, E.J., Sosa, E.M., Huebsch, W.W., Means, K., Banta, L., Thompson, G. (2012), "Inflatable plug for threat mitigation in transportation tunnels", Proceedings of the Society for the Advancement of Material and Process Engineering 2012 Conference, Baltimore, pp. 1-14.
9
Yoo, K.S. (2016), Design method of large expansion fabric-structure for flood damage mitigation in tunnel, Ph.D. Thesis, Dept. of Civil Engineering, Hoseo University, pp. 29-31.
10
Yoo, K.S., Lee, J.H., Kim, Y.D., Kim, S.H. (2015), "Model testing of leakage effect due to multi-cell inflater of rapid protection system in subsea tunnel", Journal of Korean Tunnelling and Underground Space Association, Vol. 17, No. 3, pp. 295-303.
10.9711/KTAJ.2015.17.3.295
11
Yoo, K.S., Lee, J.H., Kim, Y.D., Kim, S.H. (2016), "Friction behavior of inflatable structure system to protect rapidly flooding damages in subsea tunnel", Journal of Korean Tunnelling and Underground Space Association, Vol. 18, No. 1, pp. 109-117.
10.9711/KTAJ.2016.18.1.109
Information
  • Publisher :Korean Tunneling and Underground Space Association
  • Publisher(Ko) :한국터널지하공간학회
  • Journal Title :Journal of Korean Tunnelling and Underground Space Association
  • Journal Title(Ko) :한국터널지하공간학회 논문집
  • Volume : 22
  • No :4
  • Pages :469-484
  • Received Date : 2020-06-17
  • Revised Date : 2020-07-10
  • Accepted Date : 2020-07-14