All Issue

2014 Vol.16, Issue 3 Preview Page
31 May 2014. pp. 287-298
Abstract
References
1
1.ACI Committee 544. (1999), “Design considerations for steel fiber reinforced concrete (ACI 544.4R- 88)”, Farmington Hills (Michigan, MI): American Concrete Institute; 1988. Re-approved 1999. pp. 10-11.
2
2.ACI Committee 318. (2011), “Building code requirement for structural concrete and commentary”, Farmington Hills (Michigan, MI): American Concrete Institute; pp. 170-172.
3
3.Chiaia, B., Fantilli, A.P., Vallini, P. (2009), “Combining fiber-reinforced concrete with traditional reinforcement in tunnel linings”, Engineering Structures, Vol. 31, Issue 7, pp. 1600-1606.
4
4.Conforti, A., Minelli, Fausto, M., Plizzari, G. A. (2013), “Wide-shallow beams with and without steel fibers: A peculiar behaior in shear and flexure”, Composites: Part B, Vol. 51, pp. 282-290.
5
5.Dobashi, H., Konishi, Y., Nakayama, M., Matsubara, K. (2006), “Development of steel fiber reinforced high fluidity concrete segment and application to construction”, Tunneling and Underground Space Technology, Vol. 21, p. 422.
6
6.fib (2010), “Model code 2010, first complete draft”, Vol. 1, pp. 200-231.
7
7.Fuente, A., Pujadas, P., Balanco, A., Aguado, A. (2012), “Experiences in barcelona with the use of fibers in segmental linings”, Tunneling and Underground Space Technology, Vol. 27, pp. 60-71.
8
8.Moon, D., Kang, T., Chang, S., Lee, G., Bae, G. (2013), “Flexural performance evaluation of SFRC with design strength of 60 MPa”, Journal of Korean Tunnelling and Underground Space Association, Vol. 15, No. 3, pp. 175-186.
9
9.Rivaz, B. (2008), “Steel fiber reinforced concrete (SFRC): The use of SFRC in precast segment for tunnel linings”, World Tunnel Congress 2008- Underground Facilities for Better Environment and Safety-India, pp. 2007-2017.
10
10.Sorelli, L.G., Meda, A., Plizzari, G.A. (2005), “Bending and uniaxial tensile tests on concrete reinforced with hybrid steel fibers”, Journal of Materials in Civil Engineering, Vol. 17, No. 5, pp. 519-527.
11
11.Concrete Society (2011), “Technical report no. 63, guidance for the design of steel-fiber-reinforced Concrete”, Report of a Concrete Society Working Group, p. 35.
12
12.Tiberti, G., Plizzari, G.A., Walraven, J.C., Blom, C.B.M. (2008), “Concrete tunnel segments with combined traditional and fiber reinforcement”, Tailor Made Concrete Structures, Taylor & Francis Group, pp. 199-204.
13
13.Oh, Y.H. (2008), “Evaluation of flexural strength for normal and high strength concrete with hooked steel fibers”, Journal of the Korean Concrete Institute, Vol. 20, No. 4, pp. 531-539.
Information
  • Publisher :Korean Tunneling and Underground Space Association
  • Publisher(Ko) :한국터널지하공간학회
  • Journal Title :Journal of Korean Tunnelling and Underground Space Association
  • Journal Title(Ko) :한국터널지하공간학회 논문집
  • Volume : 16
  • No :3
  • Pages :287-298
  • Received Date : 2014-04-08
  • Revised Date : 2014-04-18
  • Accepted Date : 2014-04-21